I was very happy with the thorough checking of our HVAC systems.
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Cameron did a wonderful job. Quick, efficient, and very pleasant.
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Performed heating tune up service on all 3 systems checking all electrical components, refrigerant balance, cleaning of all furnace components, treatment of drains, performance of full combustion analysis, testing of unit start up, operation, shutdown. Customer complaint about mini split dehumidification during summer months causing high humidity when in dry mode. Tested minisplit in both heat and cool finding all electrical components and refrigerant balance within manufacturer's specifications. Referenced system manual to attempt to change dry mode settings. Will recommend a return in spring to check dry mode operation as it does not want to dehumidify without a cooling load on the building. Upstairs may require additional dehumidification but can be more accurately tested when outdoor temperatures and humidity are higher.
Performed heating tune up service on heat pump systems checking all electrical components, refrigerant balance, unit start up, operation, defrost, shutdown, cleaning of drains, Changing of customer provided filters. Everything looks and runs great! Upstairs filter is a 20x20x4
Found T6 thermostat minus button to lower temperature not working replaced with new T6 tested operation. This is under warranty.
Found capacitor to be broken not showing any micro ferrets. Compressor was drawing 2.5 A and refrigerant was not flowing. Replaced capacitor refrigerant was working fine. Compressor is now drying 4.5 which is normal for this unit. No other issues found today.
SEER 14; HSPF 8.2; EER 11.5 Make: Goodman Model: GSLZS4BA1810 Heat Pump GAMST24BU1300 Fan Coil 3KW Electric Heat Honeywell T-4 Thermostat Installation includes equipment specified above plus materials and labor to include: • All work to be completed in a professional workmanlike manner. • Goodman Factory Warranty: 10 years all parts. • One (1) year Labor Warranty provided by Comfort Central, Inc. • 100% Customer Satisfaction Guarantee for the first year. • Ten (10) Year Guarantee on Comfort Central, Inc. Workmanship. • 100% Customer Satisfaction Guarantee for the first year.
Unit is operating normally - refrigerant balance is perfect - all electrical components within manufacturers specifications - adjusted vanes on minisplit to give better air flow - removed grass from in front of outdoor unit that was impeding fan - reset remote on minisplit to 72 - recommend using ceiling fan in room to help move air around but have Mitsubishi fan reaching across the room on high speed. Recommend watching unit for a few days to track it's progress.
Found system capacitor had gone flat from 30+5 previously recorded - replaced capacitor and tested system for excessive electrical draws. Everything runs normally again.
Performed cooling tune up service on heat pump minisplit system checking all electrical components, refrigerant balance, unit start up, operation, shutdown, cleaning of filters, checking indoor and outdoor coils, treatment of drains. Everything looks and runs great!
Performed AC cooling tune up service on heat pump mini split system checking all electrical components, refrigerant balance, unit start up, operation, shutdown, cleaning of filters, checking of indoor and outdoor coils, treatment of drains. Everything looks and runs great!
Found unit compressor locked out on thermal lock out due to start capacitor failing and run capacitor starting to go out of range. Recommend replacing both at same time. System compressor needs to cool, will return tomorrow to complete repair and test system. Pulled unit outdoor disconnect to allow system to cool. Replaced run capacitor, start capacitor, and potential relay. Checked compressor operation by manually pushing contactor in. System will work now with a call for coolung.
Found system thermostat programming caused thermostat not to recognize outdoor unit. Reprogrammed thermostat and then cycled system to check operation. Everything came on normally and is working within manufacturer's specifications.
2 Ultimate Cooling Tune-Up: cleaned coils, brushed and cleaned traps, added pan treatment tablets to pan. tested and checked all controls, wiring connections. tested temperatures, checked filters. checked refrigerant temperature and pressures, tested static duct pressure. tested blower operation, tested cooling operation to ensure working within manufacturer specifications.
Ultimate Cooling Tune-Up: cleaned coils, brushed and cleaned traps, added pan treatment tablets to pan. tested and checked all controls, wiring connections. tested temperatures, checked filters. checked refrigerant temperature and pressures, tested static duct pressure. tested blower operation, tested cooling operation to ensure working within manufacturer specifications.
Ultimate Cooling Tune-Up: cleaned coils, brushed and cleaned traps, added pan treatment tablets to pan. tested and checked all controls, wiring connections. tested temperatures, checked filters. checked refrigerant temperature and pressures, tested static duct pressure. tested blower operation, tested cooling operation to ensure working within manufacturer specifications
Ultimate Cooling Tune-Up: cleaned coils, brushed and cleaned traps, added pan treatment tablets to pan. tested and checked all controls, wiring connections. tested temperatures, checked filters. checked refrigerant temperature and pressures, tested static duct pressure. tested blower operation, tested cooling operation to ensure working within manufacturer specifications.